1. Horizontal concealed high ESP ducted fan coil general description
Fan coil unit is the terminal of central air conditioning system.It consists of centrifugal fan and copper tube heat exchanger.The ceiling concealed fan coil unit can be embedded in the ceiling and merged with interior decoration. Only exposing tuyere, which save space and easy maintenance. Widely used in hotels, restaurants, factories, hospitals, exhibition hall, shopping malls, office rooms and other industrial and civil construction of the combined air-conditioning system to meet the cooling, heating and other requirements.
Product Type | High External Static Pressure Ducted Fan Coil Unit |
ESP | 120Pa (75Pa, 80Pa, 100Pa also optional) |
Pipe System | 2 pipes or 4 pipes |
Cooling Capacity | 9KW ~ 12.6KW (2 pipe system) |
Heating Capacity | 13.5KW ~ 18.9KW (2 pipe system) |
Cooling Capacity | 9KW ~ 12.6KW (4 pipe system) |
Heating Capacity | 6.5KW ~ 9.1KW (4 pipe system) |
1 | Ceiling concealed fan coil unit |
2 | High ESP ducted fan coil unit |
3 | Universal concealed fan coil unit |
4 | Floor standing exposed fan coil unit |
5 | Ultra thin exposed fan coil unit |
6 | Ceiling exposed fan coil unit |
7 | Ceiling cassette fan coil unit |
8 | Ceiling exposed & floor standing fan coil unit |
9 | Wall mounted fan coil unit |
3. High ESP ducted fan coil unit main parts
((1)Motor: Famous branded 3-speed fan motor, each motor assembled is dynamically balanced.
(2)Fan: Fans are composed of double suction centrifugal fans with aluminum impellers, with big airflow and low noise front-forward wind wheel.
(3)Cooling/heating coil: Coils are made of seamless copper tubes expanded into hydrophilic aluminum fins in continuous block.
(4)Different length drain pan: According to different needs, standard and extended length drain pan are optional.
(5)Collecting head: The connections have brass headers with female fittings and provided with easily accessible and drainage valve.
(6)Electrical connection box: All electric wires are connected to enclosed electrical terminal box, situated on the same side of the water connections.
4. Ceiling horizontal concealed high static pressure fan coil unit technical specification
Please ask salesman for detailed complete data or visit our website:
eurostarschiller.en.made-in-china.com
eurostarschiller.en.made-in-china.com
High ESP Ducted Fan Coil Unit(A Style) | ||||||||||
Model EST~ | 1000HP2 | 1200HP2 | 1400HP2 | 1000HP4 | 1200HP4 | 1400HP4 | ||||
Air flow (m3/h) | H | 1700 | 2040 | 2380 | 1700 | 2040 | 2380 | |||
M | 1280 | 1550 | 1800 | 1280 | 1550 | 1800 | ||||
L | 860 | 1050 | 1280 | 860 | 1050 | 1280 | ||||
Static pressure | Pa | 120 | 100 | 80 | 120 | 100 | 80 | |||
Rated cooling capacity | H | TH(W) | 9000 | 10800 | 12600 | 9000 | 10800 | 12600 | ||
SH(W) | 6705 | 8046 | 9387 | 6705 | 8046 | 9387 | ||||
M | TH(W) | 7290 | 8748 | 10206 | 7290 | 8748 | 10206 | |||
SH(W) | 5759 | 6911 | 8063 | 5759 | 6911 | 8063 | ||||
L | TH(W) | 5670 | 6804 | 7938 | 5670 | 6804 | 7938 | |||
SH(W) | 4649 | 5579 | 6509 | 4649 | 5579 | 6509 | ||||
Rated heating capacity | H | W | 13500 | 16200 | 18900 | 6500 | 7800 | 9100 | ||
M | 10395 | 12474 | 14556 | 5090 | 6110 | 7130 | ||||
L | 8168 | 9801 | 11435 | 4080 | 4900 | 5720 |
(1) Cooling: Inlet air temperature DB 27ºC,WB 19.5ºC; Chilled water inlet/outlet temp. 7ºC/12ºC.
(2) Heating: Inlet air temperature DB 20°C, heating water inlet/outlet temperature 60°C/50ºC.
Now we have customers in different countries and places, such as Mexico, Australia, New Zealand, Singapore, Argentina, Ukraine, Uzbekistan, Middle- East, Africa…
(2)The Guarantee of Quality: Reasonable design, Professional technicians, Stable production workers, Full-scale Equipments, Strict QA & QC system…
(3)Custom made Design:
We supply our design drawing according to customer practical situation.
(4) Technique Support:
We supply our wiring diagram, installation instructions and maintenance manual, make more easier for installation.
(5) International Trade Operation:
We have concentrated on international trade of fan coil units for many years, accumulated various experience from different customers of different countries. So we can update our operation in time according to our customers and new rules. It is helpful to clear customs and save cost and time for our customers.
6. How to choose the fan coil?
(1) Firstly need to know the application site, for example, hotel room generally choose ceiling concealed fan coil, restaurant generally choose ceiling cassette fan coil, it depends on site requirements.
(2) If need to calculate cooling capacity, please get the acreage data.
(3) Confirm the pipe system: 2 pipe or 4 pipe according to the cooling and heating source.
7.Our service
Before-sale services:
(1)Tell clients how to use our products and matters needing attention.
(2)Guide clients to choose the best and economic product, recover the investment within short time.
(3)Site inspection if client require.
In-sale services:
(1)Quality control must be inspect strictly.
(2)In accordance with the agrements stipulated in the contract.
After-sale services
(1)If the project needs our installation guidance, we can send our engineer and translator. We can also send customers installation video to teach them how to fix and operate with our product.
(2)Usually, our product warranty is 12 months since BL date, within this warranty period, all parts broken will be responsible for our factory.
For bulk order, our standard package is carton or honeycomb packing for fan coil, for safe delivery and easy to load/unload, we will stack several layers together with plastic film and packing straps tightly onto the plywood or plastic pallets.
For sample order, we generally use plywood box or honeycomb cardboard to protect.
9. Customers visit
10. Fan coil unit projects
We exported fan coils to Serbia, Romania, Greece, France, South Africa, Australia, Uzbekistan, Mexico, Argentina, etc..