AC system horizontal chilled water ceiling hidden fan coil unit

AC System Horizontal Chilled Water Ceiling Concealed Fan Coil Unit  1. Fan coil unit seriesCeiling concealed fan coil unitHigh ESP ducted fan coil unit Universal concealed fan coil unitFloor standing exposed fan coil unitUltra thin exposed fan coil unitCeiling exposed fan coil unitCeiling cassette fan coil unitCei

Featured Products

AC System Horizontal Chilled Water Ceiling Concealed Fan Coil Unit 
 
1. Fan coil unit series
AC System Horizontal Chilled Water Ceiling Concealed Fan Coil Unit

Ceiling concealed fan coil unit
High ESP ducted fan coil unit
Universal concealed fan coil unit
Floor standing exposed fan coil unit
Ultra thin exposed fan coil unit
Ceiling exposed fan coil unit
Ceiling cassette fan coil unit
Ceiling exposed & floor standing fan coil unit
Wall mounted fan coil unit

2. Ceiling concealed fan coil brief description
Fan coil units are referred to as fan coils. It is one of the end devices of an air conditioning system consisting of a small fan, a motor and a coil (air heat exchanger). When the chilled water or hot water flows through the coil pipe, heat is exchanged with the air outside the pipe, the air is cooled, and the indoor air parameters are adjusted by dehumidifying or heating. It is a commonly used cooling and heating terminal device.
Available for following models:
Cooling capacity: 1.8KW to 12.6KW
Heating capacity: 2.7KW to 18.9KW
Air flow: 200 CFM to 1400 CFM

3. Ceiling concealed fan coil unit main components
(1)Casing
Panels and frame are made of galvanized steel, properly punched for fixing both accessories and the unit itself, either to wall (vertical version) or ceiling(horizontal version).
(2)Cooling/Heating Coil
The coils are made of seamless tubes expanded into aluminum fins in continuous block. The connections have brass headers with female fittings and provided with easily.
accessible vent and drainage valve.
(3)Fan deck
The fan decks are composed of double suction centrifugal fans with metal impellers and 3-speed fan motors. Each fan motor assembly is dynamically balanced.
(4)Filter
The easily removable filter is made of filtering honeycomb polypropylene fabric and supported by an aluminum or plastic frame.
(5)Drip tray
The drip trays are made from sheet metal treated with polyester powder coating to ensure total resistance to atmospheric agents. The "L" type tray makes the units suitable for both vertical and horizontal installation.
(6)Electrical connection box
All electric wires are connected to enclosed electrical terminal block, can be situated on the opposite side to the water connections.

AC System Horizontal Chilled Water Ceiling Concealed Fan Coil Unit

4. Ceiling horizontal concealed fan coil unit technical specification
Please ask salesman for detailed complete data or visit our website:
eurostarschiller.en.made-in-china.com
eurostarschiller.en.made-in-china.com

Horizontal Concealed Fan Coil Unit (2 pipe system)
Model EST~200HC2300HC2400HC2500HC2600HC2800HC21000HC21200HC21400HC2
Air flow (m3/h)
(0/12Pa,30Pa Static Pressure)
High 34051068085010201360170020402380
Medium 2703805156607651040128015501800
Low 19026034043053071086010501280
Rated cooling capacity HTH(W)18002700360045005400720090001080012600
SH(W)134120122682335340235364670580469387
MTH(W)1485218729163645437458327290874810206
SH(W)115217282304288034554607575969118063
LTH(W)113417012268283534024536567068047938
SH(W)93013951860232527903720464955796509
Rated heating capacity HW2700405054006750810010800135001620018900
M207931194158519862378316103951247414553
L1634245032674084490165348168980111435
Horizontal Concealed Fan Coil Unit (4 pipe system)
Model EST~200HC4300HC4400HC4500HC4600HC4800HC41000HC41200HC41400HC4
Air flow (m3/h)
(0/12Pa,30Pa Static Pressure)
High 34051068085010201360170020402380
Medium 2703805156607651040128015501800
Low 19026034043053071086010501280
Rated cooling capacity HTH(W)18002700360045005400720090001080012600
SH(W)134120122682335340235364670580469387
MTH(W)1485218729163645437458327290874810206
SH(W)115217282304288034554607575969118063
LTH(W)113417012268283534024536567068047938
SH(W)93013951860232527903720464955796509
Rated heating capacity HW108016202160270032404320540064807560
M83212481663207924953326415849905821
L6549801307163419602614326739204574
Remarks:
(1)  Cooling: Inlet air temperature DB 27ºC,WB 19.5ºC; Chilled water inlet/outlet temp. 7ºC/12ºC.
(2)  Heating: Inlet air temperature DB 20°C, heating water inlet/outlet temperature  60°C/50ºC.

5. Ceiling concealed fan coil unit features
(1) Excellent performance
(2) High reliability
(3) Easy maintenance
(4) Simple installation

 
6.Why choose EUROSTARS?  
We, EUROSTARS, which established in year 2006, is a modern hi-tech enterprise, specializing in Heating Ventilation Air Conditioning and Industrial Refrigeration research, development, production, sales and engineering services.
Webiste 1: http://eurostarschiller.en.made-in-china.com/
Website 2: http://eurostarschiller.en.made-in-china.com/
 
Instagram: https://eurostarschiller.en.made-in-china.com
Facebook: https://eurostarschiller.en.made-in-china.com
Youtube https://eurostarschiller.en.made-in-china.com

1) With more certificate
2) Professional team with over more than 10 years industry knowledge
3) Oversea installation.
4) Customer-made accepted.
5) Diamond member of Made-In-China
6) Audited supplier by SGS

AC System Horizontal Chilled Water Ceiling Concealed Fan Coil Unit
AC System Horizontal Chilled Water Ceiling Concealed Fan Coil Unit

7. Our fan coil production line

Every fan coil has strict production process, including assembly, testing, packing.
AC System Horizontal Chilled Water Ceiling Concealed Fan Coil Unit
AC System Horizontal Chilled Water Ceiling Concealed Fan Coil Unit

8. Our service
Considerate after-sales service & product maintenance.You can contact us at any time.
Economical and energy-saving design scheme
Overseas engineer services
Integrated quality and profession R&D team
OEM/ODM available

 
9. Fan coil unit package and delivery
For bulk order, our standard package is carton packing for fan coil, for safe delivery and easy to load/unload, we will stack several layers together with plastic film and packing straps tightly onto the plywood or plastic pallets.
For sample order, we generally use plywood box or honeycomb cardboard to protect.
AC System Horizontal Chilled Water Ceiling Concealed Fan Coil Unit

10. Ceiling concealed fan coil installation instruction
(1) Air duct must be fireproof regulations for buildings.
(2) For horizontal air supply, N≥150 MM; if air duct is longer than 1 m, N≥200 mm.
(3) Size of M depends on air duct installation. Pressure loss of circulatory air must be consistent with outlet static pressure of the unit.
AC System Horizontal Chilled Water Ceiling Concealed Fan Coil Unit

11. Fan coil unit projects
We exported fan coils to Serbia, Romania, Greece, France, South Africa, Australia, Uzbekistan, Mexico, Argentina, etc..
AC System Horizontal Chilled Water Ceiling Concealed Fan Coil Unit

 

Contact us

Please feel free to give your inquiry in the form below We will reply you in 24 hours